Flowmeter Electromagnetic
Flowmeter Electromagnetic

Flowmeter Electromagnetic

1. Txoj kab uas hla: DN 6-DN2800
2. Hom: cais hom, hom kev sib xyaw, hom plug-in (tsim rau cov yeeb nkab diameters saum DN100)
3. Cov khoom siv hauv ob sab phlu: Neoprene, PTFE, PFA, FEP, F46
4. Electrode khoom: SS316L, HC, HB, Ti, Tan, Pt
5. Qhov tseeb: 0.2 feem pua ​​, 0.5 feem pua
6. Nruab nrab kub: -20 degree ~ 160 degree
7. Valve lub cev khoom: carbon steel, SS304, SS316L
8. Fais fab mov hom: 85VAC ~ 264VAC, 24VDC, roj teeb fais fab mov, hnub ci fais fab mov
9. Cov zis hom: mem tes tso zis, 4 ~ 20Ma tso zis, Modbus, Hart (yeem)
10. Daim ntawv txuas: clamp, xov, flange (tus qauv xaiv: DIN, ANSI, JIS)
Xa kev nug
Tsham tam sim no

1. Lub hauv paus ntsiab lus ua haujlwm:

Magnetic flow meter yog ib qho flowmeter uas siv lub hauv paus ntsiab lus ntawm electromagnetic induction los ntsuas cov dej ntws hauv cov kav dej. Nws ua haujlwm los ntawm kev siv ob lub electrodes muab tso rau ntawm ob sab ntawm cov yeeb nkab thiab txuas nrog lub tshuab hluav taws xob. Lub Circuit Court generates ib magnetic teb, uas induces ib tug voltage hla lub electrodes.

 

Thaum ib tug conductive kua ntws los ntawm ib tug yeeb nkab, ib tug voltage teeb liab proportional rau lub ceev ntawm cov kua yog generated. Qhov hluav taws xob hluav taws xob no yog ua tiav los ntawm hluav taws xob hluav taws xob thiab tso tawm kom pom raws li kev ntsuas ntws.

 

Flowmeter electromagnetic feem ntau yog siv rau hauv daim ntawv thov uas yuav tsum tau ntsuas qhov tseeb, xws li hauv kev lag luam tshuaj, tshuaj thiab dej kho. Txij li thaum tsuas yog cov hauv ob sab phlu thiab electrodes nyob rau hauv kev sib cuag nrog cov kua, yog tias koj xav ntsuas cov ndlwg ntawm corrosive los yog abrasive kua, koj yuav tsum xaiv ib tug haum electrode thiab hauv ob sab phlu khoom.

 

2. Qhov zoo:

Qhov ntsuas no muaj ntau yam zoo dua lwm hom flowmeter thiab tau dhau los ua neeg nyiam nyob rau hauv ntau yam kev siv. Ib qho ntawm qhov zoo tshaj plaws ntawm cov flowmeter electromagnetic yog nws cov peev xwm ntsuas ntau, uas suav nrog kev ntsuas cov kua dej nrog cov khoom siv hluav taws xob siab, xws li cov kua zaub mov zoo li cov kua qaub, alkalis thiab lwm cov kua dej corrosive.

 

Qhov zoo 2: Nws yog qhov siab tshaj plaws vim tias nws tsis muaj qhov txav txav, uas txhais tau hais tias tsis muaj kev siv tshuab. Qhov no feature ua rau lub cuab yeej txhim khu kev qha thiab tsis tshua muaj txij nkawm, ua rau nws yog ib qho kev xaiv zoo heev rau kev soj ntsuam tas li thiab ntsuas kev siv.

 

Qhov zoo 3: Cov khoom sib nqus flowmeters muaj ntau yam thiab tuaj yeem siv rau ntau qhov chaw ua haujlwm, suav nrog cov chaw kho dej thiab cov dej khib nyiab, cov chaw tsim tshuaj thiab chaw tsim tshuaj, cov chaw tsim khoom noj thiab dej haus, thiab cov chaw tsim khoom roj thiab roj.

 

Advantage 4: Nws ua siab ntev rau qhov hnyav ib puag ncig, muaj kev ntseeg siab, raug thiab lub sij hawm teb ceev ceev kom saib xyuas tsis tu ncua thiab ua cov txiaj ntsig ntsuas thiab txo qis qis.

 

Advantage 5: Ib qho yooj yim rau nruab thiab koom ua ke nrog lwm cov txheej txheem tswj thiab automation systems, ua rau nws zoo tagnrho rau cov kev siv niaj hnub no.

 

Zuag qhia tag nrho, nws yog ib qho kev txhim khu kev qha thiab cov nqi tsim nyog rau ntau yam kev ntsuas kev lag luam. Lawv qhov zoo dua li lwm hom ntws ntsuas, ua rau lawv xaiv thawj zaug rau cov neeg siv nrhiav qhov raug siab, kev ntseeg siab thiab kev ua haujlwm yooj yim.

 

3.Qee yam khoom duab:
Meter lub cev cov ntaub ntawv muaj xws li: carbon steel, SS304, SS316

 

Txoj kev sib txuas: xov, clamp, flange (German standard, American standard, Japanese standard)

 

Hom: integrated, split, plug-in

Clamp connection beer flow meter

Flanged beer flow meter

SS316 stainless steel electromagnetic flowmeter

40 inch stainless steel electromagnetic flowmeter

flowmeter electromagnetic

Split type electromagnetic flowmeter

Plug-in electromagnetic flowmeter

Remote electromagnetic flowmeter

Integrated Magnetic Flowmeter

 

4. Kev tiv thaiv theem taw qhia:

 

* Kev tiv thaiv qib tau muab faib ua: IP65, IP67, IP68:

 

* IP65: Dustproof thiab waterproof.

 

* IP67: Dustproof, tuaj yeem nkag rau hauv dej rau lub sijhawm luv luv

 

* IP68: Dustproof, tuaj yeem txuas ntxiv rau hauv dej (qhov no yuav tsum xaiv lub ntsuas hluav taws xob nyob deb)

 

* Cov ntaub ntawv pov thawj tawg: yog hais txog lub sijhawm uas muaj cov khoom siv hluav taws xob thiab cov khoom tawg hauv huab cua, xws li chaw nres tsheb roj, uas yuav tsum tau

 

5. Kev taw qhia txog txheej txheej:

 

Hom hauv ob sab phlu Piav

Polyurethane roj hmab

* Siv tau ntau yam: -2.5 degrees -60 degrees, haum rau nruab nrab thiab muaj zog abrasive pulp, thee slurry, av nkos, ntawv pulp, dej phwj hauv tsev, dej khib nyiab.

PTFE

* PTFE yog cov khoom siv nrog cov tshuaj ruaj khov tshaj plaws ntawm cov yas; Nws yog resistant rau boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali thiab ntau yam organic solvents, tab sis nws tsis resistant rau chlorine trifluoride, kub kub oxygen fluoride, loj txaus kua fluorine, kua Corrosion los ntawm oxygen thiab ozone.

 

Scope ntawm daim ntawv thov: -25 degrees -140 degrees, muaj zog corrosive tshuaj xws li concentrated acid thiab alkali, haus dej, mis nyuj, npias, dej haus thiab lwm yam kev huv si media.

PFA

* Zoo hydrophobicity thiab tsis-stickiness, muaj zog kub kub kuj.

* Zoo heev corrosion kuj, resistant rau muaj zog acid, muaj zog alkali, organic hnyav thiab ntau yam ntsev tov.

* Scope ntawm daim ntawv thov: -25 degree -140 degree tsis muaj zog abrasive nruab nrab (cov kua muaj cov khoom impurities, uas yuav rub tawm tsam hauv ob sab phlu thiab electrodes thaum cov kua ntws), huv nruab nrab.

 

6.Electrode taw qhia:

 

Raws li cov yam ntxwv ntawm cov xov xwm sib txawv, nws yog ib qho tseem ceeb heev uas yuav tau xaiv cov electrode uas haum tshaj plaws.

 

Hom hluav taws xob Piav
SWB 316L

Nws yog siv rau kev lag luam dej, dej phwj tuaj, inorganic acid, thiab tsis muaj zog corrosive nruab nrab, thiab tuaj yeem siv dav hauv roj av, tshuaj, urea, vinylon thiab lwm yam lag luam.

Tungsten carbide electrode Haum rau cov kua uas tsis yog corrosive, tab sis hnav-resistant,

Hastelloy B (HB)

Nws muaj corrosion kuj zoo rau tag nrho cov concentration ntawm hydrochloric acid hauv qab lub boiling point, thiab kuj yog resistant rau corrosion los ntawm non-oxidizing acids, alkalis, thiab non-oxidizing ntsev tov xws li sulfuric acid, phosphoric acid, hydrofluoric acid, thiab organic acids.

Hastelloy B (HC)

Resistant rau oxidizing acids, xws li nitric acid, sib xyaw acids los yog sib xyaw ntawm chromic acid thiab sulfuric acid, thiab kuj tiv taus oxidizing ntsev. Xws li corrosion ntawm hypochlorite tov thiab dej hiav txwv saum toj ib txwm kub.

Titanium (Ti)

Corrosion tsis kam rau dej hiav txwv, ntau yam chlorides thiab hypochlorites, oxidizing acids (xws li fuming nitric acid), organic acids, alkalis, thiab lwm yam, tab sis tsis mus rau ntshiab txo acids (xws li sulfuric acid, hydrochloric acid).

Tantalum (Ta)

Nws muaj kev tiv thaiv corrosion zoo heev, zoo ib yam li iav. Tsuas yog hydrofluoric acid, fuming sulfuric acid thiab alkali, nws yog resistant rau corrosion los ntawm yuav luag tag nrho cov chemical media (xws li boiling point hydrochloric acid, nitric acid, aqua regia thiab sulfuric acid hauv qab 175 degrees), thiab tsis resistant rau corrosion nyob rau hauv alkali.

Platinum-iridium alloy

Siv rau tag nrho cov tshuaj, resistant rau corrosion (xws li kua qaub, alkali, ntau yam ntsev), tab sis tsis resistant rau aqua regia.

 

7.Cov khoom peb tsim yuav yog 100 feem pua ​​​​calibrated ua ntej tawm hauv lub Hoobkas kom paub meej 100 feem pua ​​​​lub Hoobkas dhau tus nqi thiab qhov raug raws li cov qauv thoob ntiaj teb.

 

 

8.On-site installation rooj plaub:

 

Electromagnetic flowmeter works

9.RFQ:

1. Q: Yuav ua li cas txog qhov tseeb ntawm koj cov khoom siv?

 

A: Peb cov khoom yuav raug kuaj ib-rau-ib ua ntej tawm hauv lub hoobkas. Peb qhov tseeb yog 0.5 feem pua, thiab qhov tseeb tshaj plaws mus txog 0.2 feem pua ​​.

 

2. Lo lus nug: Yuav ua li cas xaiv lub hauv ob sab phlu thiab electrode kom raug?

 

A: Yog tias koj tsis muaj txoj kev npaj rau kev xaiv hauv ob sab phlu thiab electrodes, koj tuaj yeem qhia rau peb tus neeg muag khoom tus neeg sawv cev rau qhov ntsuas nruab nrab, thiab nws yuav xaiv qhov kev pom zoo rau koj.

 

3. Q: Koj cov khoom puas txhawb nqa kev txiav txim? MOQ hauv PCS yog dab tsi?

 

A: Yog, peb txhawb cov qauv, thiab peb cov MOQ yog 1PCS.

 

4. Q: Koj puas tuaj yeem xa cov khoom tuaj rau peb lub tebchaws?

 

A: Tau kawg! Peb yuav xaiv hom kev lag luam ntawm kev thauj mus los rau koj raws li qhov hnyav thiab ntim ntawm koj cov khoom. Peb txhawb nqa kev thauj mus los, Los ntawm huab cua, Los ntawm railway, Los ntawm hiav txwv.


Yog tias koj muaj lus nug ntxiv, thov hu rau peb, peb yuav npaj cov neeg muag khoom thiab cov kws tshaj lij los teb tag nrho koj cov lus nug thiab xaiv cov khoom tsim nyog rau koj.
Henan Junyuan Automation Equipment Co., Ltd. txais tos koj nug txhua lub sijhawm! ! !

Cim npe nrov: flowmeter electromagnetic, Tuam Tshoj, lwm tus neeg, manufacturers, hoobkas, lag luam wholesale, yuav, nqe, kev muag khoom