Dab tsi yog qhov ua rau kev ntsuas qhov yuam kev ntawm electromagnetic flowmeter

May 12, 2022 Tso lus

Electromagnetic flowmeters yog siv dav hauv petrochemical, tshuaj, dej phwj kho, kev txuag dej, kev ua liaj ua teb, npias, mis nyuj, ntsuas dej haus thiab lwm yam lag luam vim lawv qhov zoo ntawm tsis muaj kev poob siab, siab precision, thiab tus nqi nruab nrab. Lawv ua lub luag haujlwm tseem ceeb hauv kev ntsuas dej ntws. . Txawm li cas los xij, hauv cov ntawv thov, vim yog kev ua haujlwm tsis raug, kev xaiv cov khoom siv tsis tsim nyog, thiab kev teeb tsa tsis raug cai, kev ntsuas qhov yuam kev yog qhov nyuaj los zam, ua rau cov neeg siv tsis meej pem. Yog li ntawd, cov tuam txhab lag luam yuav tsum tau them sai sai rau ntau yam uas ua rauelectromagnetic flowmeteryuam kev.

 

Feem ntau, cov kev cuam tshuam tseem ceeb ntawm kev ua yuam kev ntawm electromagnetic flowmeter tuaj yeem muab faib ua peb pawg: 1. Kev xaiv tsis raug, 2. cuam tshuam los ntawm qhov nruab nrab thiab sab nraud cuam tshuam.

 

China Electromagnetic Flowmeter Manufacturer

1. Qhov khiav ceev ntawm cov kua yuav tsum tau ntsuas: qhov khiav ceev ntau yam uas yuav ntsuas tau los ntawm lub electromagnetic flowmeter feem ntau yog 0.5 ~ 10m / s, thiab economic flow velocity ntau yog 1.5 ~ 3m / s . Hauv kev siv tiag tiag, lub puab txoj kab uas hla ntawm lub raj ntsuas yuav tsum tau txiav txim siab raws li qhov ntsuas qhov ntws thiab qhov sib txawv ntawm qhov nrawm uas tuaj yeem ntsuas los ntawm electromagnetic flowmeter.

 

2. Kev xaiv cov khoom siv hluav taws xob thiab cov khoom siv hauv ob sab phlu: Cov khoom siv electrode thiab hauv ob sab phlu yog nyob rau hauv kev sib cuag ncaj qha nrog cov kua yuav tsum tau kuaj. Cov khoom siv electrode thiab hauv ob sab phlu yuav tsum raug xaiv raws li cov yam ntxwv ntawm cov kua yuav tsum tau kuaj (xws li corrosiveness, abrasiveness, thiab lwm yam) thiab kev ua haujlwm kub. Ua rau muaj teeb meem xws li ceev adhesion, corrosion, scaling, hnav, thiab hauv ob sab phlu deformation, ua rau kev ntsuas yuam kev.

 

3. Excitation hom ntawm excitation stabilityelectromagnetic flowmeter: muaj DC excitation, AC sine yoj excitation thiab dual-frequency rectangular yoj excitation, thiab lwm yam. DC excitation yog nquag electrode polarization thiab DC cuam tshuam teeb meem. Qhov zaus square nthwv dej excitation muaj ob qho tib si zoo xoom taw tes ruaj khov ntawm qhov tsawg zaus square nthwv dej excitation thiab muaj zog tsub kom muaj peev xwm ntawm lub siab zaus square yoj excitation rau lub suab nrov. Nws yog ib txoj hauv kev zoo tshaj plaws excitation. Hauv kev siv tswv yim, kev ruaj ntseg ntawm cov khoom siv hluav taws xob thiab qhov zaus yuav tsum tau ua kom ntau li ntau tau los xyuas kom meej qhov chaw sib nqus lub zog tas li thiab txo qhov kev ntsuas qhov yuam kev tshwm sim los ntawm kev hloov pauv ntawm lub zog sib nqus.

 

4. Kev ntsuas cov kua dej sib xyaw: Thaum siv lub ntsuas hluav taws xob electromagnetic los ntsuas qhov ntws ntawm cov kua dej sib xyaw ua kua (xws li cov dej uas muaj sediment), yog siv cov electromagnetic flowmeter calibrated los ntawm cov kua ib-theem, kev ntsuas yuam kev yuav tshwm sim. Nruab lub flowmeter sensor nyob rau hauv cov yeeb nkab ncaj seem uas yuav ua rau cov kua-kem theem sib cais.

 

Kev ntsuas kua ua kua:

 

1. Cov conductivity ntawm cov kua kuaj tau hloov drastic: thaum lub conductivity ntawm cov tshuaj ntsuam xyuas yog loj, nws yuav ua rau ib tug loj fluctuation ntawm cov displayed nqi. Yog tias qhov teeb meem loj heev, nws yog qhov nyuaj rau kev tswj xyuas kom ua tiav kev ua haujlwm ib txwm; Thaum nws qis, nws yog qhov nyuaj rau cov electrode kom ua tiav cov txiaj ntsig zoo. Yog hais tias cov conductivity ntawm cov kua yuav tsum tau ntsuas yog qis dua qhov kev txwv thaum lub sij hawm ua hauj lwm, lub electromagnetic flowmeter tsis tuaj yeem kuaj pom ib txwm. Nyob rau hauv qhov kev pom ntawm cov xwm txheej no, ua ntej ntawm tag nrho cov, peb yuav tsum xav txog qhov xav tau tiag tiag thiab muab cov qauv tsim nyog thiab cov kev xav tau los xaiv hom electromagnetic flowmeter; thib ob, nruab lub reactor los yog cov yeeb nkab ncaj seem kom paub meej tag nrho cov khoom sib xyaw thiab txhawb kev ua tiav ntawm cov tshuaj tiv thaiv zoo; dua, Rov ua dua qhov flowmeter hom xaiv.

 

2. Ntsuas cov npuas ua kua lossis cov raj tsis puv: Rau cov npuas, qhov chaw tseem ceeb ntawm cov npuas yog cov npuas uas cov roj yaj hauv cov kua tsim tawm mus rau hauv lub xeev dawb thiab cov npuas nqus los ntawm lub ntiaj teb sab nraud. Cov nqi ntws uas muaj cov npuas loj tuaj yeem cuam tshuam qhov tseeb ntawm qhov ntsuas. Yog hais tias lub npuas taub yog loj heev, los yog txawm tshaj tus nqi ntawm lub electrode txoj kab uas hla, lub xeev tsis ruaj tsis khov yuav tshwm sim thaum lub sij hawm ntsuas thiab tso saib txheej txheem, thiab kev hloov pauv tsis tuaj yeem zam tau. Nyob rau hauv qhov kev pom ntawm qhov teeb meem no, thawj zaug, cov roj collector tuaj yeem ntsia tau rau ntawm lub tshuab electromagnetic flowmeter, thiab kev ua haujlwm tawm tuaj yeem ua raws li lub voj voog; thib ob, txoj haujlwm teeb tsa tuaj yeem hloov pauv tau; thib peb, cov yeeb nkab ntsug tuaj yeem ntsia tau rau ntawm electromagnetic flowmeter kom paub meej hauv qab-up orientation; thib plaub, thaum txhim kho lub sensor, tsis txhob mus ze rau qhov chaw nres nkoj tawm; fifth, nruab lub sensor ntawm qhov chaw tswj valve, ntws los ntawm nws, los yog downstream ntawm lub twj tso kua mis.

 

3. Cov conductivity ntawm cov kua kuaj no tsawg dhau: qhov txo qis ntawm cov conductivity ntawm cov kua kuaj yuav ua rau cov zis impedance ntawm electrode, thiab cov nyhuv load tshwm sim los ntawm input impedance ntawm converter yuav ua rau kev ntsuas yuam kev. Yog tias qhov tseeb conductivity qis dua qhov qis dua, qhov ntsuas yuav Yog tias nws tsis ua haujlwm zoo, tus nqi tso tawm yuav hloov pauv. Kev daws: xaiv lwm yam khoom siv hluav taws xob qis hluav taws xob uas ua tau raws li qhov yuav tsum tau ua, xws li capacitiveelectromagnetic flowmeters; los yog xaiv lwm lub hauv paus ntsiab lus flowmeters, xws li orifice daim hlau.

 

4. Cov kua ntsuas yog asymmetrical: Thaum lub ntsuas ntsuas, cov kua ntsuas yog asymmetrical, thiab feem ntau muaj ob qhov sib xyaw ua ke: ib qho yog ib qho vortex flow; lwm qhov yog qhov ncaj ncaj ntws raws lub axis ntawm cov kav dej, qhov ntim ntawm cov kua yog qhov tseem ceeb ntawm cov yeeb nkab seem. Raws li qhov tsis txaus ntawm cov kav dej ncaj nraim, cov dej ntws tuaj yeem siv los kho; Thib ob, xyuas kom meej tias lub puab txoj kab uas hla ntawm cov yeeb nkab thiab lub puab txoj kab uas hla ntawm lub flowmeter nyob rau hauv ib tug tsim nyog ntau yam ntawm upstream thiab downstream muaj tus nqi tib yam; thib peb, tso cov yeeb nkab ncaj nraim rau sab saud.

 

5. Muaj txheej txheej hauv lub raj ntsuas: Electromagnetic flowmeters feem ntau siv los ntsuas cov kua dej tsis huv. Cov kua dej tsis huv muaj qee cov sediment thiab lwm yam khoom, uas ua rau cov pa phem ntawm electrode nto los yog cov kav dej ntawm cov electromagnetic flowmeter, uas ua rau muaj kev ua yuam kev hauv kev ntsuas. Nyob rau hauv teb rau qhov teeb meem no, ua ntej, lub electromagnetic flowmeter yuav tsum tau ntxuav tsis tu ncua; thib ob, tus nqi ntws yuav tsum tau nce ntxiv los tswj nws ntawm 4m / s thiab lub xeev siab tshaj plaws; thib peb, cov ntaub ntawv xws li polytetrachloroethylene yuav tsum tau siv.

 

1. Qhov chaw electromagnetic cuam tshuam converter thiab sensor: lub cable yog ntev, thiab nyob rau hauv ib tug muaj zog electromagnetic ib puag ncig, nws yog ib qho yooj yim los mus cuam tshuam, uas ua rau nonlinear ntsuas ntawm lub ntsuas, uas yog ib qho nyuaj rau tso saib ib txwm. Hauv kev teb rau qhov teeb meem no, ua ntej, qhia txog kev tiv thaiv kev ntsuas, thiab cov cable tuaj yeem nkag tau rau hauv cov yeeb nkab steel hauv av, thiab siv cov shielded cable uas ua tau raws li tus qauv; thib ob, qhov ntev ntawm lub cable yuav tsum luv luv kom tsim nyog; thib peb, ua kom ntev deb ntawm qhov muaj zog magnetic teb.

 

2. Cov teeb meem ntawm kev sib txuas cov cables Lub ntsiab lus ntawm daim ntawv thov electromagnetic flowmeter yog siv ib qho tshwj xeeb cable los txuas rau lub converter thiab lub sensor los tsim ib qho kev ua tiav. Yog li ntawd, qhov chaw hla ntu ntawm tus neeg xyuas pib, lub capacitance, thiab qhov chaw cable yuav muaj kev cuam tshuam tsis zoo. Nyob rau hauv qhov kev pom ntawm qhov teeb meem no, ua ntej ntawm tag nrho cov, nws yog ib qho tsim nyog los xyuas kom meej tias cov cable hom ua tau raws li qhov yuav tsum tau ua, kom paub txog kev sib txuas zoo ntawm qhov kawg, thiab tiv thaiv qhov tshwm sim ntawm cov pob qij txha nruab nrab; thib ob, tswj qhov ntev, feem ntau yog luv dua qhov zoo dua

 

3. Grounding teeb meem Vim hais tias cov zis teeb liab ntawm lub sensor me me, feem ntau tsuas yog ob peb millivolts, txhawm rau txhim kho lub peev xwm tiv thaiv kev cuam tshuam, xoom lub peev xwm ntawm lub sensor yuav tsum tau grounded ntawm nws tus kheej thiab kev ntseeg siab, thiab cov ntsiab lus hauv av ntawm lub sensor tso zis teeb liab yuav tsum tau hluav taws xob txuas nrog cov kua los ntsuas. Lub grounding kuj ntawm lub sensor yuav tsum tsawg tshaj li 10Ω. Thaum cov yeeb nkab txuas lub sensor yog coated nrog ib txheej insulating los yog cov yeeb nkab uas tsis yog xim hlau siv, lub nplhaib hauv av yuav tsum tau muab ntsia rau ntawm ob sab ntawm lub sensor (lub electromagnetic flowmeter tsim tam sim no muaj 3 electrodes: zoo electrode, tsis zoo electrode, grounding. electrode), thiab hauv av nws ntseeg tau kom cov kua dej hauv av, thiab cov dej muaj peev xwm yog tib yam li hauv av muaj peev xwm.

 

4. Electrode thiab excitation coil symmetrical point mounting point vibration

 

Lub excitation coil thiab electrodes ntawmelectromagnetic flowmeteryuav tsum tau symmetrical. Thaum lawv yog asymmetrical, qhov sib txawv yuav tshwm sim hauv cov txheej txheem tsim khoom, thiab nws yog qhov nyuaj los xyuas kom meej qhov ntsuas tau. Tsis tas li ntawd, qhov chaw teeb tsa yuav tsum ua kom tau raws li tus qauv kev tiv thaiv kev vibration siab, txwv tsis pub qhov tseeb ntawm qhov ntsuas qhov ntsuas tsis tuaj yeem lav, thiab txawm tias lub ntsuas ntsuas yuav tsis ua haujlwm zoo.

 

Lub flowmeter txuas nrog hauv av xaim, thiab lub hauv paus taw tes ntawm lub sensor tso zis teeb liab yuav tsum tau hluav taws xob txuas nrog cov kua dej ntsuas. Lub grounding kuj ntawm lub sensor yuav tsum tsawg tshaj li 10Ω. Thaum lub raj xa dej txuas lub sensor yog coated nrog ib txheej insulating los yog cov kav dej uas tsis yog xim hlau siv, lub nplhaib hauv av yuav tsum tau muab ntsia rau ntawm ob sab ntawm lub sensor thiab muab tso rau hauv av kom ntseeg tau tias cov kua dej hauv av thiab cov dej muaj peev xwm zoo ib yam. raws li lub hauv av muaj peev xwm.