Electromagnetic Dej Flowmeter
Electromagnetic Dej Flowmeter

Electromagnetic Dej Flowmeter

1. Tuam Tshoj sab saum toj kaum electromagnetic dej flowmeter manufacturers
2. High quality, high precision thiab tsis tshua muaj nqi electromagnetic dej flow meter chaw tsim tshuaj paus
3. Txhawb OEM thiab ODM high-end customization (logo customization, nameplate customization, tsos thiab specification customization)
Xa kev nug
Tsham tam sim no

 

Tuam Tshoj electromagnetic dej ntws meter manufacturers

Henan Junyuan Automation Equipment Co., Ltd. yog tsim nyob rau hauv 2002 thiab muaj kev R & D, ntau lawm thiab muag kev. Muab ntau yam khoom siv ntsuas ntsuas, siab, ntsuas kub thiab ntsuas cov kua dej rau cov neeg siv khoom suav thiab thoob ntiaj teb. Peb txhawb ntau yam customizations (xws li: LOGO, nameplate, hom, tsos xim, loj, thiab lwm yam.)

 

 

Lub hauv paus ntsiab lus thiab Scope ntawm kev siv cov cuab yeej:

 

Lub electromagnetic dej flowmeter yog ib qho cuab yeej siv lub hauv paus ntsiab lus ntawm Faraday's electromagnetic induction txoj cai los ntsuas qhov tam sim no ntws thiab cumulative flow ntawm conductive kua dhau los ntawm cov kav dej. Vim nws qhov kev ntsuas siab, kev ruaj ntseg thiab kev ntseeg siab, ntau yam kev sib txuas lus, thiab ntau yam zoo, nws tuaj yeem txuas nrog ntau yam khoom siv tswj thiab tau siv dav hauv ntau yam lag luam xws li dej, tshuaj lom neeg kev lag luam, khoom noj khoom haus, thiab tshuaj.

 

Lub cuab yeej muaj lub converter thiab ib lub sensor uas muaj ob lub coils tso rau ntawm txoj cai kaum rau ib leeg. Thaum cov kua ntws los ntawm cov yeeb nkab, qhov voltage yog generated uas yog proportional rau tus nqi ntws. Tom qab ntawd qhov voltage yog ntsuas los ntawm electromagnetic sensor thiab tus nqi ntws yog xam.

 

Qhov txiaj ntsig tseem ceeb ib qho: Nws tsis cuam tshuam los ntawm qhov ntws siab, kub thiab viscosity ntawm cov kua ntsuas. Cov cuab yeej kuj yog ib qho yooj yim rau nruab thiab tswj, muaj lub neej ntev thiab yuav tsum tau kho me ntsis los yog calibration.

 

Qhov txiaj ntsig tseem ceeb thib ob: Nws muab qhov tseeb siab txawm tias nyob rau hauv ib puag ncig hnyav xws li cov xuab zeb, tshem tawm cov khib nyiab thiab tshuaj lom neeg. Tsis tas li ntawd, cov cuab yeej tsis muaj qhov txav txav, txhais tau tias nws tsis tshua muaj kev cuam tshuam rau kev hnav thiab tsim kua muag, ua rau nws ruaj khov thiab siv tau zoo.

Zuag qhia tag nrho, nws cov versatility, raug thiab durability ua rau nws cov khoom ntawm kev xaiv rau kev ntsuas cov kua ntws nyob rau hauv ntau yam industries, thiab nws yooj yim ntawm installation thiab txij nkawm ua kom nws muaj peev xwm muab tau yooj yim integrated rau hauv uas twb muaj lawm systems.

DN400 carbon steel flowmeter

668M

Kev koom tes thoob ntiaj teb

532M

Kev tshuaj xyuas zoo

90M

Order tau txais

236M

Ua tiav qhov project

Kev xaiv cov khoom siv hauv ob sab phlu:

Kev xaiv hauv ob sab phlu ntawm lub magnetic flowmeter yog qhov tseem ceeb heev. Nws yog ib qho tsim nyog los xaiv cov khoom siv hauv ob sab phlu zoo tshaj plaws raws li cov yam ntxwv ntawm qhov nruab nrab tau ntsuas, uas yog tus yuam sij rau kev ua haujlwm ruaj khov, qhov tseeb thiab kev pabcuam lub neej ntawm cov cuab yeej ntsuas. Cov lus qhia luv luv rau cov khoom siv hauv qab no feem ntau siv hauv ob sab phlu:

         Magnetic flow meter liningRubber lining for magnetic flowmeter

Rubber hauv ob sab phlu:

 

Daim ntawv thov ntau: 0 degree -80 degree tsis muaj zog acid, muaj zog alkali, muaj zog oxidizing nruab nrab. Nws tuaj yeem ntsuas qhov tsis muaj zog abrasive media, dej, dej ntws, dej dej, dej khib nyiab, dej phwj tuaj, ntawv pulp thiab av nkos thiab lwm yam kua dej.

Polytetrafluoroethylene (PTFE):

 

Scope ntawm daim ntawv thov: -25 degrees rau 140 degrees, muaj zog corrosive tshuaj xws li concentrated acid thiab concentrated alkali, thiab huv si media xws li dej haus, mis nyuj, npias, thiab dej haus.

Fluorinated Ethylene Propylene (F46):

 

Scope ntawm daim ntawv thov: -25 degrees rau 100 degrees tsis muaj zog abrasive media, huv si media.

Kev faib tawm ntawm cov khoom siv electrode:

Kev xaiv electrode ntawm magnetic dej flowmeter yog qhov tseem ceeb heev. Nws yog ib qho tsim nyog los xaiv cov khoom siv electrode uas haum tshaj plaws raws li cov yam ntxwv ntawm cov kua uas yuav tsum tau ntsuas, xws li cov kua dej huv, dej, muaj cov kua qaub thiab alkali, thiab cov kua muaj cov khoom siv (xaiv cov khoom hnav-resistant). Cov hauv qab no yog cov khoom siv electrode feem ntau siv:

1.Molybdenum-muaj stainless hlau (316L):

 
A: Scope ntawm daim ntawv thov: mis nyuj, dej haus, npias thiab lwm yam zaub mov-qib kua, industrial dej, irrigation dej, dej phwj tuaj, inorganic acids, weakly corrosive media, thiab lwm yam.

2.Stainless Steel Coated Tungsten Carbide:

 
A: Nws yog tsim rau cov xov xwm uas tsis yog-corrosive, hnav-resistant, thiab muaj impurities thiab cov khoom me me hauv cov kua.

3.Hastelloy electrode:

 

A: Nws muaj kev tiv thaiv corrosion zoo rau tag nrho cov ntsiab lus ntawm hydrochloric acid hauv qab qhov kub thiab txias, thiab tseem tiv taus corrosion los ntawm non-oxidizing acids, alkali thiab non-oxidizing ntsev tov xws li sulfuric acid, phosphoric acid, hydrofluoric acid thiab organic acids. . Corrosion los ntawm cov tshuaj hypochlorite thiab dej hiav txwv saum toj ib txwm kub.

4. Titanium (Ti):

 

A: Resistant corrosion los ntawm seawater, ntau yam chlorides thiab hypochlorites, oxidizing acids (xws li fuming nitric acid), organic acids, alkali, thiab lwm yam.

5. Tantalum (Ta) :

 

A: Nws muaj kev tiv thaiv corrosion zoo heev thiab tiv taus corrosion los ntawm yuav luag tag nrho cov khoom siv tshuaj (xws li kub taw tes hydrochloric acid, nitric acid, aqua regia thiab sulfuric acid hauv qab 175 degrees). Nws tsis tiv taus corrosion hauv alkali.

 

Calibration lub sij hawm thiab calibration ntsiab lus:

 

Tag nrho peb cov flowmeters dhau los ua pov thawj ib-rau-ib zaug ua ntej tawm hauv lub Hoobkas kom ntseeg tau 100% Hoobkas tsim nyog tus nqi.

 

Txhua lub sijhawm ntsuas yuav tsum tsis pub tsawg tshaj li lub sijhawm ntsuas luv tshaj plaws uas tau tso cai los ntawm lub cuab yeej, thiab lub sijhawm luv tshaj plaws yuav tsum tsis pub tsawg tshaj 30s, thiab rau cov cuab yeej Class A (electromagnetic flowmeters nrog cov zis zaus, plug-in electromagnetic flowmeters nrog cov zis ntau zaus) Yuav tsum xyuas kom meej tias tus nqi ntawm tus txheeb ze yuam kev ntawm tus naj npawb ntawm pulses tso zis los ntawm cov flow meter nyob rau hauv ib tug calibration yog tsis ntau tshaj 1/3 ntawm lub repeatability ntawm cov flow meter raug kuaj.

 

Cov ntsiab lus calibration thaum ntsuas qhov ua tau zoo ntawm qhov ntsuas feem ntau tau teev tseg raws li hauv qab no: Rau cov cuab yeej Class A, cov ntsiab lus ntsuas yuav tsum suav nrog qmin, {{0}}.07qmax, 0 .15qmax, 0.25qmax, 0.4qmax, 0.7qmax thiab qmax. Thaum tus nqi ntws ntawm ob peb lub ntsiab lus calibration tsawg dua qmin, Qhov calibration point no tuaj yeem tsis quav ntsej. Rau Chav Kawm B cov twj paj nruag (xws li electromagnetic flowmeters uas tso tawm cov cim analog lossis tuaj yeem tso ncaj qha mus rau tam sim ntawd), cov ntsiab lus ntsuas ntsuas yuav tsum suav nrog tsawg kawg 5 cov ntsiab lus pov thawj suav nrog qmin thiab qmax, thiab muab faib sib npaug.

 

Cov txheej txheem tsim khoom yooj yim ntawm qhov ntsuas:
 
 

Los ntawm tej yeeb nkab--- vuam---electrode---puab---coil--- sealing--- polishing--- pleev xim --- kuaj ---packing.

Electromagnetic flowmeter conduit
Electromagnetic flowmeter accessories
Internal structure of electromagnetic flowmeter
Fixed magnetic flowmeter coil
Sealed Magnetic Flowmeter Coil

Magnetic flow meter polishing and painting

Magnetic flowmeter calibration
Magnetic flowmeter packaging
Magnetic flowmeter
Send magnetic flowmeter
core zoo
Xaiv tus neeg muag khoom uas ua haujlwm zoo tshaj rau koj.

Cov khoom siv raw khoom, R & D, ntau lawm, muag, thiab kev pabcuam kev sib koom ua ke

Ua tiav kev tsim kho, R & D, tsim, tsim khoom, thiab muab cov saw kaw kaw kom ntseeg tau tias lub neej zoo.

Lub hom phiaj muaj zog

Lub Hoobkas tsim nyog tus nqi yog 100%, pab cov neeg nruab nrab thiab cov neeg siv kawg hauv ntau dua 60 lub teb chaws thoob ntiaj teb, nrog kev txaus siab ntawm ntau dua 98%.

Electromagnetic flowmeter calibration device

Nyob rau hauv-tob sib sau ua ke technology los ntawm 2022 mus rau tam sim no

Nrog cov thev naus laus zis tseem ceeb, patents, hom thiab kev muag khoom thoob ntiaj teb, peb nyob hauv kev lag luam ua lag luam hauv cov ntsuas ntsuas thiab ntsuas.

Kev sib koom ua ke cov cuab yeej siv tshuab thev naus laus zis thiab koom tes nrog cov qauv hauv network
Sib koom ua ke cov tswv yim sib koom ua ke los tsim kev lag luam ua ke

 

DN1000 electromagnetic wastewater flow meter calibration video:


FAQ

Q: Qhov tsawg kawg nkaus txiav txim kom muaj nuj nqis PCS yog dab tsi?

A: Peb qhov kev txiav txim yam tsawg kawg nkaus yog 1PCS. Peb muaj cov khoom siv raw khoom zoo thiab cov khoom muag, thiab peb tuaj yeem siv cov khoom xa tuaj.

Q: Peb puas tuaj yeem kho peb tus kheej lub npe?

A: Tau kawg. Kuv yog cov chaw tsim khoom thiab tuaj yeem txais ntau yam kev hloov kho.

Q: Txoj kev them nyiaj thiab nqe lus them nqi yog dab tsi?

A: Peb lees txais: TT them nyiaj, credit card online them nyiaj, RMB them, Western Union them, LC them, cov nqe lus them nqi yog raws li koj qhov kev yuav khoom ib zaug, sib tham nrog peb tus neeg muag khoom.

Q: Yog tias nws yog 100PCS, lub sijhawm xa khoom ntev npaum li cas?

A: Peb muaj cov khoom hauv Tshuag, peb lub sijhawm kwv yees ntau lawm yog 5 hnub ua haujlwm rau 100PCS.

 

 

 

 

 

Cim npe nrov: electromagnetic dej flowmeter, Tuam Tshoj, lwm tus neeg, manufacturers, hoobkas, lag luam wholesale, yuav, nqe, kev muag khoom