Flow Meter
Flow Meter

Flow Meter

1. Txoj kab uas hla: DN 6-DN2800
2. Hom: hom chaw taws teeb, hom kev sib txuas, hom ntsaws
3. Cov khoom siv hauv ob sab phlu: neoprene, PTFE, PFA, FEP, F46
4. Electrode khoom: SS316L, HC, HB, Ti, Tan, Pt
5. Qhov tseeb: 0.2%, 0.5%
6. Nruab nrab kub: -20 degree ~ 160 degree
7. Cov khoom siv lub cev: carbon steel, SS304, SS316L
8. Kev sib txuas hom: clamp, xov, flange (tus qauv xaiv: DIN, ANSI, JIS)
Xa kev nug
Tsham tam sim no

1. Daim ntawv thov:

Emflowmeter yog ib qho khoom siv tshwj xeeb rau kev ntsuas ntsuas ntawm cov kua ua kua. Nws yog qhov zoo tagnrho rau ntau daim ntawv thov thiab dav siv hauv petrochemical, roj thiab dej phwj tuaj, dej khib nyiab, pulp, slurry, dej kho, khoom noj khoom haus thiab dej haus, tshuaj thiab lwm yam lag luam.

 

① Hauv kev lag luam kho dej, nws yog siv los ntsuas cov dej ntws, dej khib nyiab thiab lwm yam kua dej.

 

② Hauv kev lag luam khoom noj thiab dej haus, cov ntsuas ntws tau siv los ntsuas qhov ntws ntawm cov khoom xyaw sib txawv xws li mis nyuj, dej thiab kua qab zib.

 

③ Hauv kev lag luam kws tshuaj, nws yog siv los ntsuas cov dej ntws hauv cov txheej txheem tsim khoom.

 

④ Lub ntsuas hluav taws xob kuj tseem siv hauv HVAC tshuab los ntsuas qhov ntsuas cua, siab poob thiab kev siv zog. Nws kuj tseem siv tau hauv cov chaw tsim hluav taws xob los ntsuas qhov ntws ntawm condensate.

 

Feem ntau, hom flowmeter no muaj ntau yam kev siv thiab yog ib qho tseem ceeb rau txhua qhov chaw ntawm lub neej. Nws qhov tseeb, yooj yim ntawm kev siv, thiab kev ntseeg siab ua rau nws yog qhov kev xaiv nrov rau kev ntsuas ntws.

 

4 inch stainless steel electromagnetic flowmeter

 

2. Kev xaiv hauv ob sab phlu:

 

Xaiv cov khoom siv hauv ob sab phlu zoo rau lub tshuab nqus hlau nplaum yog qhov tseem ceeb kom tau txais kev ntsuas qhov tseeb, ua kom lub neej ntawm flowmeter thiab txo tus nqi tu. Los ntawm kev xav txog chemistry, kub, tshaj tawm, siab thiab conductivity ntawm cov kua ntsuas, peb cov engineers tuaj yeem xaiv cov ntaub ntawv zoo tshaj plaws rau koj daim ntawv thov tshwj xeeb.

 

Cov khoom siv hauv ob sab phlu Piav

Neoprene hauv ob sab phlu

Roj kuj, hnyav kuj, oxidation kuj, dav acid thiab alkali, ntsev thiab lwm yam nruab nrab corrosion kuj, tsis resistant rau oxidative nruab nrab corrosion.

* Nws muaj elasticity zoo heev thiab hnav tsis kam. Tab sis qhov txias tsis kam yog qhov tsis zoo.

* Siv tau ntau yam: 1.0 degree -80 degree tsis muaj zog acid, muaj zog alkali, muaj zog oxidizing nruab nrab. Nws tuaj yeem ntsuas cov dej tsis muaj zog abrasive, av nkos thiab ore pulp.

PTFE (polytetrafluoroethylene) Ib qho ntawm cov ntaub ntawv siv ntau tshaj plaws niaj hnub no vim nws cov tshuaj tiv thaiv zoo heev, kub tsis kam, tsis tshua muaj coefficient ntawm kev sib txhuam thiab tsis tshua muaj porosity. Nws yog qhov tsim nyog rau kev ntsuas cov kua corrosive xws li acids, alkalis, thiab cov kuab tshuaj organic. PTFE kuj yog ib qho yooj yim los ntxuav thiab tswj, ua rau nws yog ib qho kev xaiv nrov hauv cov khoom noj thiab tshuaj lag luam.

PFA

(Perfluoroalkoxy)

PFA (Perfluoroalkoxy) yog lwm cov khoom siv fluoropolymer uas muaj cov khoom zoo sib xws rau PTFE, tab sis nrog cov neeg kho tshuab zoo heev thiab ua kom kub tsis kam. Nws yog qhov zoo tagnrho rau kev ntsuas cov kua dej uas muaj corrosive thiab muaj zog acids, yog li nws feem ntau siv rau hauv kev lag luam tshuaj thiab petrochemical.

F46

(Fluorinated Ethylene Propylene)

* Hydrophobic thiab tsis nplaum.

* Kev tiv thaiv corrosion yog thib ob tsuas yog PFA.

* Thaum lub siab tsis zoo yuav tsum tau muaj siab, hlau mesh tuaj yeem ntxiv los txhim kho lub peev xwm tsis zoo.

* Kev hnav tsis zoo.

* Siv tau ntau yam: -25 degrees -100 degrees ntawm cov khoom siv tsis muaj zog, cov xov xwm huv.

 

3.Electrode cov ntaub ntawv thiab cov cuab yeej piav qhia:

 

Cov khoom siv electrode siv los ntawm em flow meter yog qhov tseem ceeb heev, nws cuam tshuam ncaj qha rau qhov raug thiab kev ntseeg tau ntawm kev ntsuas ntws. Cov khoom siv electrode yuav tsum sib haum nrog cov kua ntsuas, yuav tsum tsis txhob corrode, thiab yuav tsum muaj peev xwm tiv taus cov kev ua haujlwm ntawm cov flowmeter.

 

Cov khoom siv hluav taws xob Piav

SWB 316L

(Molybdenum-muaj stainless hlau)

Nws tuaj yeem tiv taus cov dej tsis muaj zog corrosive thiab tuaj yeem siv rau kev ntsuas dej ntawm cov khoom noj, xws li: dej haus, npias, dej haus, thiab lwm yam.
Nws tseem tuaj yeem siv rau hauv cov dej hauv dej, dej phwj tuaj, inorganic acid, tsis muaj zog corrosive media, thiab tuaj yeem siv dav hauv roj av, tshuaj, urea, vinylon thiab lwm yam lag luam.

Ti

(Titanium)

Corrosion tsis kam rau dej hiav txwv, ntau yam chlorides thiab hypochlorites, oxidizing acids (xws li fuming nitric acid), organic acids, alkalis, thiab lwm yam, tab sis tsis mus rau ntshiab txo acids (xws li sulfuric acid, hydrochloric acid). Txawm li cas los xij, yog tias cov kua qaub muaj cov tshuaj oxidizing (xws li nitric acid, FE+++, CU++), corrosion yuav raug txo.

Ta

(Tantalum)

Nws muaj kev tiv thaiv corrosion zoo heev, zoo ib yam li iav. Tsuas yog hydrofluoric acid, fuming sulfuric acid thiab alkali, nws yog resistant rau corrosion ntawm yuav luag tag nrho cov tshuaj media (xws li boiling point hydrochloric acid, nitric acid, aqua regia thiab sulfuric acid hauv qab 175 degrees), tab sis nws tsis yog corrosion resistant nyob rau hauv alkali.

HC/HB

(Hastelloy)

Nws yog resistant rau corrosion los ntawm oxidizing acids, xws li nitric acid, tov kua qaub los yog tov media ntawm chromic acid thiab sulfuric acid, thiab kuj resistant rau corrosion los ntawm oxidizing ntsev xws li FE+++, CU++ los yog lwm yam oxidants. Xws li cov corrosion ntawm cov tshuaj hypochlorite saum toj ib txwm kub thiab dej hiav txwv.

Platinum-iridium alloy

Siv rau tag nrho cov tshuaj, resistant rau corrosion (xws li kua qaub, alkali, ntau yam ntsev), tab sis tsis resistant rau aqua regia.

 

4.Electrode thiab Coil Structure Diagram:

 

Electrode structure diagram of electromagnetic flowmeterElectromagnetic flowmeter coil structure diagram

                                                                                   

 

Electromagnetic flowmeter sensor appearance                Electromagnetic flowmeter appearance structure diagram

                           

 

5.Electromagnetic flowmeter kauj:


Kev siv tag nrho cov tooj liab coils ua rau cov hlau nplaum tsim los ntawm cov flowmeter ruaj khov, kev ntsuas qhov tseeb yog lav, kev pabcuam lub neej ntev dua, thiab cov flowmeter ua haujlwm ruaj khov.

 

All flowmeters use full copper coilsElectromagnetic flowmeter full copper coilElectromagnetic flowmeter coil

 

 

6. Cov khoom muag txaus:


Lub em flow meter muaj txaus Tshuag ntawm cov khoom ib nrab tiav thiab txaus cov khoom tiav los xyuas kom meej tus nqi xa tuaj raws sij hawm.

 

Electromagnetic flowmeter sensorElectromagnetic flowmeter conduit

 

7.Flow Meter Calibration Unit:

Peb lub Hoobkas muaj cov cuab yeej ua haujlwm tshaj lij thiab cov kws tshaj lij calibration engineers. Thaum cov av nkos daim ntawv thov flowmeter tawm ntawm lub Hoobkas, tus kws tshaj lij calibration engineer siv {{0}}} taw tes calibration txoj kev los ntsuas cov flowmeter ib-rau-ib los xyuas kom meej tias qhov tseeb ntawm cov flowmeter tuaj yeem ncav cuag {{5} }.5%, mus txog 0.5%. mus txog 0.2%.

 

8.On-site installation daim duab:

 

Electromagnetic flowmeter works

9.FAQ:

 

1. Q: Koj puas yog cov chaw tsim khoom?

 

A: Yog, peb muaj 20 xyoo ntawm kev tsim khoom hauv kev tsim cov flowmeters, thiab tau tsim kev koom tes nrog tsoomfwv Suav lub chaw txuag dej thiab ntau lub lag luam loj. Tib lub sijhawm, cov khoom lag luam tseem raug xa tawm mus rau ntau dua 40 lub teb chaws thoob ntiaj teb, thiab tau txais txiaj ntsig zoo los ntawm cov neeg koom tes thiab cov neeg siv khoom.

 

2. Q: Koj puas txhawb kev hloov kho?

 

A: Yog. Peb txhawb OEM, ODM, peb tuaj yeem tsis tsuas yog kho lub hom, tab sis kuj txhawb ntau yam kev hloov kho raws li cov duab kos uas koj muab.

 

3. Q: Yuav ua li cas txog qhov tseeb ntawm koj qhov flowmeter?

 

A: Qhov tseeb ntawm peb cov flowmeter yog {{0}}.5%, thiab qhov siab tshaj tuaj yeem ncav cuag 0.2%.

 

4. Q: Yuav ua li cas txog kev ruaj ntseg ntawm koj flowmeter?

 

A: Peb flowmeter yog lav rau 24 lub hlis. Yog tias qhov kev puas tsuaj tsis yog tshwm sim los ntawm cov neeg tsim vim li cas, peb tuaj yeem hloov nws nrog lub flowmeter tshiab ntawm tib tus qauv.

 

6.Q: Yuav them li cas? Txoj kev them nyiaj twg tau txais kev txhawb nqa?

 

A: Peb txhawb: credit card online them nyiaj, TT them nyiaj, Western Union them thiab LC them

 

 

Yog tias koj muaj lus nug ntxiv, thov koj xav tiv tauj peb, peb yuav muaj cov neeg muag khoom muag los teb rau koj. Henan Junyuan Automation Equipment Co., Ltd. txais tos koj nug txhua lub sijhawm!

Cim npe nrov: em flow meter, Tuam Tshoj, lwm tus neeg, manufacturers, hoobkas, lag luam wholesale, yuav, nqe, kev muag khoom