magnetic flow meter dej khib nyiab
magnetic flow meter dej khib nyiab

magnetic flow meter dej khib nyiab

1. Txoj kab uas hla: DN 6-DN2800
2. Hom: cais hom, hom kev sib xyaw, hom plug-in (tsim rau cov yeeb nkab diameters saum DN100)
3. Cov khoom siv hauv ob sab phlu: Neoprene, PTFE, PFA, FEP, F46
4. Electrode khoom: SS316L, HC, HB, Ti, Tan, Pt
5. Qhov tseeb: 0.2%, 0.5%
6. Nruab nrab kub: -20 degree ~ 160 degree
7. Valve lub cev khoom: carbon steel, SS304, SS316L
8. Fais fab mov hom: 85VAC ~ 264VAC, 24VDC, roj teeb fais fab mov, hnub ci fais fab mov
9. Cov zis hom: mem tes tso zis, 4 ~ 20Ma tso zis, Modbus, Hart (yeem)
10. Daim ntawv txuas: clamp, xov, flange (tus qauv xaiv: DIN, ANSI, JIS)
Xa kev nug
Tsham tam sim no

1. Khoom nta:

Lub tshuab nqus hlau nqus dej khib nyiab yog ib yam khoom siv uas ntsuas qhov ntim ntawm cov kua dej hauv cov yeeb nkab raws li Faraday txoj cai ntawm electromagnetic induction. Lub sensor muaj cov coil excitation, peb electrodes (zoo electrode, tsis zoo electrode, hauv av electrode), stainless hlau hlau conduit, thiab hauv ob sab phlu (raws li cov xov xwm sib txawv, xaiv cov ntaub ntawv sib txawv). Lub converter tsis tsuas yog ua tau raws li qhov xav tau ntawm cov khoom siv hauv tsev, tab sis kuj muaj 4 ~ 20mA cov zis tam sim no, cov zis hluav taws xob, RS485 kev sib txuas lus, Hart (yeem) raws tu qauv, kev hloov kho thiab tswj. Nws yog tam sim no dav siv nyob rau hauv kev lag luam tshuaj, kev tiv thaiv ib puag ncig, metallurgy, tshuaj, Papermaking, dej mov thiab kua thiab lwm yam industrial technology thiab kev tswj departments. Ntxiv nrog rau kev ntsuas qhov ntws ntawm cov kua dej dav dav, qhov ntsuas no tseem tuaj yeem ntsuas qhov ntim ntawm cov kua-cov khoom sib tov, cov kua dej siab, cov ntsev, cov kua qaub muaj zog, thiab cov kua qaub alkali.


Split  Mag FlowmeterWastewater flow meter
Stainless steel wastewater flow meterIntegrated wastewater flow meter

2. Qhov zoo:

⑴. Kev ntsuas kua tsis cuam tshuam los ntawm kev hloov pauv ntawm cov kua dej ntom ntom, qhov kub thiab txias, viscosity, siab, thiab conductivity;


⑵. Xaiv cov khoom siv hauv ob sab phlu thiab electrode kom raug, uas muaj qhov zoo tshaj plaws corrosion kuj thiab hnav tsis kam;


⑶. Txoj kab uas hla engineering series yog DN10-DN2800. Muaj ntau txoj kev xaiv rau cov ntaub ntawv sensor thiab electrode;


⑷. Cov hloov pauv tau muab faib ua ib hom (ib hom ib thooj) thiab cais hom (split type);


⑸. Cov cuab yeej pov thawj tawg tuaj yeem siv rau hauv qhov chaw tawg-pov thawj;


⑹. Kev muab khoom tuaj yeem xaiv tau: 85VAC-265VAC, 18VDC-36VDC, roj teeb fais fab mov, hnub ci fais fab mov;


3. Kev xaiv cov khoom siv electrode:

Kev xaiv cov khoom siv electrode tseem ceeb heev. Ua ntej, koj yuav tsum txiav txim siab cov yam ntxwv ntawm qhov nruab nrab uas yuav tsum tau ntsuas, xws li dej, dej haus, npias thiab lwm yam kua uas tsis yog corrosive. Koj tuaj yeem xaiv SS316 electrode. Yog tias nws yog dej phwj tuaj lossis dej khib nyiab, thov ua ntej paub meej tias nws yog cov dej phwj hauv tsev lossis cov dej phwj tuaj. Yog tias nws yog cov dej khib nyiab hauv tsev, koj tuaj yeem xaiv SS316L electrode. Yog tias nws yog dej khib nyiab, thov lees paub tus nqi PH ua ntej. Yog tias nws yog corrosive, xaiv Hastelloy lossis titanium electrode raws li tus yam ntxwv. Yog hais tias nws yog corrosive heev, nws yog qhov zoo tshaj plaws los siv tantalum electrode.


4. Internal coil:

Cov khoom siv hlau nplaum sib nqus dej khib nyiab ntawm Henan Junyuan Automation Equipment Co., Ltd. txhua tus siv tag nrho cov tooj liab coils nrog kev ua haujlwm ruaj khov, uas ua kom lub sijhawm ruaj khov ntawm cov ntsuas dej ntws, ntsuas qhov tseeb, kev ua haujlwm ntev, thiab txuag cov nqi kho mob.


Electromagnetic flowmeter coilWastewater flow meter coil


5.Technical parameter rooj:

Max ntws tus nqi

 15m/s

Qhov tseeb

±0.5% ,±0.2%

Cov dej conductivity

>5 μS / cm2

Nominal siab

{{0}}.6Mpa,1.0Mpa, 1.6Mpa, 4.0Mpa (kev cai rau siab

Calibre

DN 6-DN3000

Cov khoom siv liner

PTFE, PFA, F46, Neoprene, Polyurethane

Hluav taws xob

SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum-iridium

Ambient humidity

5-100%RH( txheeb ze humidity)

Ambient kub

-25 degree rau +60 degree

Kev ntsuas ntau

1500: 1, ntws tus nqi<15m/s

Hom qauv

Integrate hom, Chaw taws teeb hom, Insertion type, ex-proof type

Kev tiv thaiv qib

IP65 (tus qauv), IP68 (yeem)

Ex-proof Mark

ATEX

Fais fab mov

24V, 220V, 3.6V roj teeb

Cov zis tawm

4-20Ma, pulse

Kev sib txuas lus raws tu qauv

RS485 (Modbus), Hart

Cov khoom txheem

JB/T 9248-1999 electromagnetic flowmeter


6. Taw qhia rau cov ntaub ntawv hauv ob sab phlu:

Cov khoom siv hauv ob sab phlu

Lub ntsiab kev ua tau zoo





PTFE

1. Cov khoom siv ruaj khov tshaj plaws ntawm cov yas hauv cov khoom siv uas tiv taus kub kub hydrochloric acid, sulfuric acid thiab aqua regia, tab sis kuj tiv taus cov kua qaub thiab ntau yam organic solvents, intolerance chlorine trifluoride, kua oxygen, siab tshaj tawm kua oxygen, ozone corrosion.

2.Kev hnav tsis zoo

PFA

Corrosion kuj nrog PTEF, muaj zog tiv thaiv tsis zoo siab


F46

1. Corrosion kuj nrog PTEF.

2.Can tiv taus qis hnav thiab tsim kua muag.

3. Muaj zog tiv thaiv tsis zoo siab.



Neoprene

1.Muaj kev yooj yim heev, qib siab ntawm tensile quab yuam, zoo hnav tsis kam.

2.Resistant mus rau qhov tsis tshua muaj concentrated acid, alkali, ntsev nruab nrab corrosion, corrosion resistant rau oxidizing media.



Polyurethane

1.Nws muaj kev hnav zoo heev (sib npaug rau 10 npaug ntawm cov roj hmab ntuj).

2 acid, alkali kev ua haujlwm tsis zoo.

3 Tsis txhob siv dej sib xyaw nrog cov kuab tshuaj organic.


7. Cuam tshuam ntau lub rooj:

Flow rate----Flow velocity comparison table

202104261347597a2a08d637f54843be90f4c7fb6a4981

01

1

2

3

4

5

15

15

0.0064

0.6362

1.2723

1.9085

2.5447

3.1809

9.5426

20

0.0113

1.1310

2.2619

3.3929

4.5239

5.6549

16.9646

25

0.0177

1.7671

3.5343

5.3014

7.0686

8.8357

26.5072

40

0.0452

4.5239

9.0478

13.5717

18.0956

22.6195

67.8584

50

0.0707

7.0686

14.1372

21.2058

28.2743

35.3429

106.0288

65

0.1195

11.9459

23.8919

35.8377

47.7836

59.7295

179.1886

80

0.1810

18.0956

36.1911

54.2867

72.3823

90.4779

271.4336

100

0.2827

28.2743

56.5487

84.8230

113.0973

141.3717

424.1150

150

0.6362

63.6173

127.2345

190.8518

254.4690

318.0863

954.2588

200

1.1310

113.0973

226.1947

339.2920

452.3893

565.4846

1696.4600

300

2.5447

254.4690

508.9380

763.4070

1017.8760

1272.3450

3817.0351

350

3.4636

346.3606

692.7212

1039.0818

1385.4424

1731.8030

5195.4089

400

4.5239

452.3893

904.7787

1357.1680

1809.5574

2261.9467

6785.8401

450

5.7256

572.5553

1145.1105

1717.6658

2290.2210

2862.7763

8588.3289

500

7.0686

706.8583

1413.7167

2120.5750

2827.4334

3534.2917

10602.8752

600

10.1788

1017.8760

2035.7520

3053.6281

4071.5041

5089.3801

15268.1403

700

13.8544

1385.4424

2770.8847

4156.3271

5541.7694

6927.2118

20781.6354

800

18.0956

1809.5574

3619.1147

5428.6721

7238.2295

9047.7868

27143.3605

900

22.9022

2290.2210

4580.4421

6870.6631

9160.8842

11451.1050

34353.3157

1000

28.2743

2827.4334

5654.8668

8482.3002

11309.7336

14137.1669

42411.5008

1200

40.7150

4071.5041

8143.0082

12214.5122

16286.0163

20357.5204

61072.5612

1400

55.4177

5541.7694

11083.5389

16625.3083

22167.0778

27708.8472

83126.5416

1600

72.3823

7238.2295

14476.4589

21714.6884

28952.9179

36191.1474

108573.4421

1800

91.6088

9160.8842

18321.7684

27482.6525

36643.5367

45804.4209

137413.2627

2000

113.0973

11309.7336

22619.4671

33929.2007

45238.9342

56548.6678

169646.0033


8.Daim ntawv pov thawj peb tau txais:

Xws li daim ntawv tso cai tsim khoom, daim ntawv pov thawj CE, daim ntawv pov thawj ISO, daim ntawv pov thawj tawg, thiab lwm yam.

Certification


9. Hoobkas saib:

Flow meter factory pictureSS304 electromagnetic flowmeter

Magnetic Flow Meter factory


10. Kev txheeb xyuas video:

Tsis hais txog ntawm txoj kab uas hla ntawm cov yeeb nkab, peb cov electromagnetic flowmeters tau lees tias yuav tsum tau ntsuas tsawg kawg ob zaug ib-rau-ib zaug ua ntej tawm hauv lub Hoobkas, xyuas kom muaj 100% Hoobkas tsim nyog tus nqi. Cov neeg siv tuaj yeem nruab thiab siv lawv ncaj qha tom qab tau txais cov khoom.



11.FAQ

Q: Koj cov khoom puas muaj lub sijhawm lav?


A: Yog, peb muaj ob xyoos lav.


Q: Koj cov khoom puas txhawb kev hloov kho?


A: Yog, peb txhawb OEM thiab ODM.


Q: Koj puas muaj koj lub Hoobkas?


A: Yog, peb yog cov chaw tsim khoom nrog ntau tshaj 20 xyoo ntawm kev tsim khoom los ntawm 2002 txog tam sim no. Peb lub tuam txhab tau muab faib rau hauv kev lag luam hauv tsev thiab chaw ua lag luam thoob ntiaj teb.


Yog tias koj muaj lus nug ntxiv, thov hu rau peb thiab peb yuav npaj cov neeg muag khoom tshaj lij los teb tag nrho koj cov lus nug! ! ! Txhua tus npoj yaig ntawm Henan Junyuan Automation Equipment Co., Ltd. txais tos koj cov lus nug txhua lub sijhawm! ! !

Cim npe nrov: magnetic flow meter wastewater, Tuam Tshoj, lwm tus neeg, manufacturers, hoobkas, lag luam wholesale, yuav, nqe, kev muag khoom