1. Product Overview:
Lub turbine flow meter yog lub ntsuas ntsuas nrawm siv los ntsuas qhov ntim ntawm cov viscosity tsawg, cov kua dej tsis sib xws uas ntws tsis tu ncua los ntawm cov kav dej kaw. Lub sensor outputs ib lub teeb liab proportional rau cov kua ntim thiab muab faib mus rau hauv tam sim no zaub hom thiab mem tes tso zis hom. Hom mem tes yog siv los ua ke nrog cov khoom siv sib xyaw ua ke los yog cov khoom siv tswj, thiab tuaj yeem siv los ntsuas qhov tam sim no ntws thiab cov kua dej ntau ntxiv. Flow thiab tswj. Cov cuab yeej ua kua turbine tuaj yeem ntsuas dej, dej siab cov ntsiab lus roj, cov dej phwj tuaj, roj av, roj av, roj teeb, npias, haus mis nyuj thiab lwm yam kua dej hauv video. Nws muaj cov yam ntxwv ntawm high precision, yooj yim txij nkawm, yooj yim installation thiab tsawg tus nqi ntawm kev siv. Raws li cov neeg siv xav tau, ntau hom tso zis tuaj yeem hloov kho kom ua tiav cov haujlwm sib txawv: cov qauv tso tawm tam sim no, cov khoom siv mem tes, cov qauv analog tam sim no tso tawm, cov kua dej sib xyaw ua ke, cov khoom siv tam sim no, thiab lwm yam.
|
|
|
|
|
|
|
|
|
|
|
|
2. Lub hauv paus ntsiab lus ntawm kev ua hauj lwm thiab kev ua haujlwm:
Digital turbine flow meter yog cov cuab yeej siv dav hauv cov txheej txheem kev lag luam los ntsuas cov kua dej kom raug. Nws yog siv los ntsuas qhov ntim ntawm cov kua uas dhau los ntawm ib lub cuab yeej dhau lub sijhawm tshwj xeeb. Flow meter muaj ib lub impeller, thiab kev sib hloov ceev ntawm lub impeller yog proportional rau tus nqi ntws ntawm cov kua. Tus naj npawb ntawm cov kiv puag ncig ntawm lub turbine yog suav los ntawm digital sensor txuas nrog cov khoom siv hluav taws xob tso tawm kom pom qhov ntsuas kev nyeem ntawv.
Hom ntsuas ntsuas no yog qhov tseeb, txhim khu kev qha, thiab muaj lub sijhawm teb ceev. Nws muab cov txiaj ntsig tau meej txawm tias siv nrog cov kua dej khov lossis cov kua dej uas muaj cov khoom tshem tawm. Thiab nws yog ib qho yooj yim rau nruab thiab tsis tas yuav tu txhua hnub.
Cov khoom siv tau dhau los ua ib feem tseem ceeb ntawm ntau qhov kev lag luam, suav nrog tshuaj lom neeg, roj av, kev ua zaub mov thiab cov chaw kho dej. Nws pab txhim kho cov txheej txheem tsim khoom, tswj cov dej ntws thiab saib xyuas kev siv peev txheej. Nws yog ib qho kev daws teeb meem uas muaj txiaj ntsig zoo uas ua rau kom muaj txiaj ntsig zoo, txo cov nqi tsim khoom thiab txhim kho tag nrho cov txiaj ntsig zoo.
Hauv kev xaus, kua turbine flowmeters yog ib qho txiaj ntsig zoo rau kev tsim khoom lag luam. Nws muab cov ntaub ntawv raug, lub sijhawm tiag tiag uas pab txhim kho kev nyab xeeb ntawm chaw ua haujlwm, txo qis sijhawm thiab txuag nqi.
3. Khoom nta:
※ Cov neeg raug siab, feem ntau mus txog ±{{0}}.5%, hom precision siab txog ± 0.2%;
※ Nrog kev rov ua tau zoo, xws li nquag calibration lossis online calibration, qhov tseeb siab heev tuaj yeem ua tiav. Nws muaj peb lub ntsiab lus kho ntawm qhov ntsuas coefficient thaum lub sij hawm kev sib hais haum, ntse them nyiaj rau cov nonlinearity ntawm qhov ntsuas coefficient, thiab tuaj yeem ua qhov kho ntawm qhov chaw;
※ Tag nrho cov ntaub ntawv siv tau yuav tsis ploj hauv 10 xyoo ntawm kev siv hluav taws xob;
※ Dav dav, txoj kab uas hla ntawm cov kav dej nruab nrab thiab loj tuaj yeem ncav cuag 1:20, thiab txoj kab uas hla ntawm cov kav dej me me tuaj yeem ncav cuag 1:10;
※ Compact thiab lub teeb yuag qauv, yooj yim installation thiab txij nkawm, loj ncig muaj peev xwm;
※ Tsim nyog rau kev ntsuas high-voltage, tsis muaj qhov yuav tsum tau ntawm lub cev ntsuas, ua kom yooj yim los ua cov twj paj nruag siab;
Muaj ntau hom tshwj xeeb sensors, uas tuaj yeem tsim raws li kev xav tau tshwj xeeb ntawm cov neeg siv khoom, xws li hom kub qis, ob txoj kev, hom hauv av, hom tshwj xeeb rau cov xuab zeb sib tov, thiab lwm yam.
※ Nws tuaj yeem ua rau hauv hom plug-in, haum rau kev ntsuas txoj kab uas hla loj, nrog kev poob siab me me thiab tus nqi qis. Cov cuab yeej tuaj yeem raug tshem tawm yam tsis muaj kev txiav tawm, thiab yooj yim rau nruab thiab tswj;
4.Converter zaub mov cov lus:
|
Tus lej |
Kab lus |
Lub ntsiab lus |
Parameter xaiv los yog ntau yam |
|
1 |
Q - Unit
m3/h |
Xaiv chav ntsuas dej ntws Default (0) |
0: m/h 6: t/h3 1: m/m 7: t/m3 2: l/h 8: kg/h 3: l/m 9: kg/m 4: SG/h 10: lb/h 5: SG/m 11: lb/m |
|
2 |
Q - Mode qw real |
Xaiv rau Algorithm Default (0) |
0: cov khoom ntim ntim 1. Cov pa loj txaus |
|
3 |
Q - Factor [P/m3] 3600.00 |
Teem lub tso tawm coefficient |
Teem lub meter coefficient hauv P / m3 Default (3600) |
|
4 |
Qhov ntom [kg/m3] 1000.0 |
Teeb qhov ceev ntawm cov kua |
Chav tsev ntawm qhov ntom ntom ntawm cov kua dej yog teem rau kg / m3 Default (1000.0) |
|
5 |
Q - 20 mA m3/h 1000.0 |
Teem lub Upper flow limit Default (1000) |
Tus nqi ntws thaum 20mA cov teeb liab tam sim no tso tawm yuav tsum tau teeb tsa thiab yuav tsum tsis txhob yog 0.Units yog tib yam li cov chav khiav dej num |
|
6 |
Q The Cut - Zero [0-50]% 0.0 |
Teeb lub Flow min txwv Default ({0}}.0) |
Txiav tawm los ntawm % ntawm kev tso tawm tag nrho Cov nqi sib txawv ntawm 0 mus txog 50 |
|
7 |
Damp (Tsuas yog TB2WE) |
Teeb lub Damp lub sij hawm ntawm cov zis tam sim no default (4) |
Teem lub sijhawm damping ntawm cov zis tam sim no, uas yog siv kom tsis txhob muaj qhov hloov pauv ntawm cov zis tam sim no. Qhov ntau yog 2 ~ 32, thiab chav tsev yog vib nas this |
|
8 |
Hart Chaw Nyob / Chaw Nyob 0 |
Teem HART sub-chaw nyob los yog modbus-rs485 chaw nyob Default (0) |
Default (0) Ob Lub Hlau 2WE qauv nyob hauv HART cov khoom siv sub-chaw nyob, ntau yam 0-15 Peb-xaim qauv 3WE yog nruab nrog qhov chaw nyob ntawm 485, xws li ntawm 0 mus rau 255 |
|
9 |
COM teeb (Tsuas yog TB3WE) COM{0}}OFF |
Teem baud tus nqi Default ("OFF") |
Tsuas yog TB3WE "OFF" los tua kev sib txuas lus kom txuag tau lub zog. "4800" thiab "9600" yog cov khoom ntaus nqi; |
|
10 |
Clear Q |
Pib dua Qt |
input password "70" thiab muab tso rau hauv kom tshem tawm cov accumulator |
5.Flow ntau lub rooj:
|
Nominal txoj kab uas hla (mm) |
Li qub flow range thiab ncua kev khiav hauj lwm |
|
|
(m3/h) |
(m3/h) |
|
|
4 |
0.04-0.25 |
0.04-0.4 |
|
6 |
0.1-0.6 |
0.06-0.6 |
|
10 |
0.2-1.2 |
0.15-1.5 |
|
15 |
0.6-6 |
0.5-5 |
|
20 |
0.8-8 |
0.45-9 |
|
25 |
1-10 |
0.5 -10 |
|
32 |
1.5-15 |
0.8-1 |
|
40 |
2-20 |
1-20 |
|
50 |
4-40 |
2-40 |
|
65 |
7-70 |
5-70 |
|
80 |
10-100 |
7-100 |
|
100 |
20 -20 |
10-200 |
|
125 |
25-250 |
13-250 |
|
150 |
30-300 |
15-300 |
|
200 |
80-800 |
40-800 |
|
Qib raug |
±0.5% |
±1% |
6. Xov txuas loj:
|
|
|
|||||
|
DN4-DN10 threaded kev twb kev txuas sensor (nrog rau cov yeeb nkab ncaj seem) |
DN15 ~ DN50 threaded kev twb kev txuas sensor |
|||||
|
Calibre (mm) |
L (mm) |
H (mm) |
G |
|||
|
Pulse yam |
Kev tawg-pov thawj mem tes hom |
4-20 hom tso zis ntau lawm |
||||
|
4 |
225 |
140 |
145 |
145 |
G1/2 |
|
|
6 |
225 |
140 |
145 |
145 |
G1/2 |
|
|
10 |
345 |
145 |
150 |
145 |
G1/2 |
|
|
15 |
75 |
145 |
150 |
150 |
G1 |
|
|
20 |
80 |
150 |
155 |
155 |
G1 |
|
|
25 |
100 |
155 |
160 |
160 |
G1 1/4 |
|
|
32 |
140 |
175 |
180 |
180 |
G2 |
|
|
40 |
140 |
180 |
185 |
180 |
G2 |
|
|
50 |
150 |
185 |
190 |
190 |
G2 1/2 |
|
|
Lus Cim: Cov qauv xov tuaj yeem hloov kho, thiab ntau yam xov xwm thoob ntiaj teb tau txais. |
||||||
7.Flange kev twb kev txuas loj lub rooj:
|
|
|||||
|
Flange txuas daim duab |
|||||
|
Calibre (mm) |
L (mm) |
H (mm) |
Txheem siab |
||
|
Pulse yam |
Kev tawg-pov thawj mem tes hom |
4-20 hom tso zis ntau lawm |
|||
|
15 |
75 |
175 |
180 |
180 |
4.0Mpa |
|
20 |
80 |
185 |
190 |
190 |
|
|
25 |
100 |
200 |
205 |
205 |
|
|
32 |
140 |
210 |
215 |
215 |
|
|
40 |
140 |
215 |
220 |
220 |
|
|
50 |
150 |
230 |
235 |
235 |
|
|
65 |
170 |
255 |
260 |
260 |
1.6 Mpa |
|
80 |
200 |
260 |
265 |
265 |
|
|
100 |
220 |
285 |
290 |
290 |
|
|
125 |
250 |
310 |
315 |
315 |
|
|
150 |
300 |
345 |
350 |
350 |
|
|
200 |
350 |
395 |
400 |
400 |
|
|
Lus Cim: Cov qauv flange thiab qib siab, ntws ntsuas ntsuas qhov ntev, thiab lwm yam tuaj yeem hloov kho. |
|||||
8.Installation qauv daim duab:
|
|
|
1. Cov lim 2. Cov yeeb nkab ncaj ua ntej 3. Lub impeller 4. Lub impeller preamplifier 5. Case 6. Tom qab cov yeeb nkab ncaj Tag nrho lub rooj qauv |
|
|
|
DN15 ~ 40 sensor qauv daim duab thiab installation loj 1. Case 2. Qhia ua ntej ib tug 3. impeller 4. Lub impeller ua rau ib tug 5. Tom qab preamplifier |
|
|
|
DN50 ~ 200 sensor qauv daim duab thiab installation loj 1. Lub pob bearing 2. pob bearing qhia ua ntej 3. Lub flange 4. flange plhaub 5. Preamplifier 6. Impeller 7. bearing 8. Bearing axis |
9. Workshop sensor ntau lawm daim duab:
|
|
|
|
|
|
10.Workshop flow sensor video:
11.FAQ:
1. Lo lus nug: Dab tsi yog cov khoom siv sensor?
A: Cov khoom siv sensor suav nrog: SS304 thiab SS316.
2. Lo lus nug: Nws ua tau li cas?
A: Peb cov txheej txheem qhov tseeb ib txwm yog {{0}}.5%, thiab qhov tseeb siab tshaj plaws tuaj yeem ncav cuag 0.2% (qhov tshwj xeeb yuav tsum tau ua).
3.Q: Yam tsawg kawg nkaus txiav txim kom muaj nuj nqis PCS?
A: Peb MOQ yog 1PCS.
4. Q: Yog tias them nyiaj tiav, lub sijhawm xa khoom ntev npaum li cas?
A: Tom qab peb tau txais cov nyiaj them poob haujlwm, kev tsim khoom tsawg dua 50PCS yuav tsum siv 7 hnub ua haujlwm. Lub sij hawm xa tuaj: Peb tus neeg muag khoom tuaj yeem suav lub sijhawm xa khoom raws li qhov koj yuav khoom thiab txoj kev xa khoom koj xaiv.
5.Q: Txoj kev them nyiaj yog dab tsi?
A: Cov kev them nyiaj peb txhawb nqa: TT them nyiaj, RMB them, Western Union them, credit card online them, LC them.
Yog tias koj muaj lus nug ntxiv, thov hu rau peb thiab peb yuav npaj cov neeg muag khoom thiab cov kws tshaj lij los teb tag nrho koj cov lus nug. Henan Junyuan Automation Equipment Co., Ltd. txais tos koj nug txhua lub sijhawm! ! !
Cim npe nrov: digital turbine flow meter, Suav teb, lwm tus neeg, manufacturers, hoobkas, lag luam wholesale, yuav, nqe, kev muag khoom





















